I.7.3. Density Balance Adjust
- To adjust the density balance of the main scanning direction by scanning the output test pattern.
- The correction value adjusted by this function is applied to the following:
Function |
Menu |
Correction value adjusted items |
---|---|---|
Copy function |
[Original Type] |
|
Utility mode |
[User Settings] -> [Printer Settings] -> [Basic Settings] -> [Color Setting] |
|
Print function (printer driver settings) |
[Printer Settings] -> [Quality] -> [Color Setting] |
<Procedure>
- Select [Printer (resolution)] or [Printer (Gradation)].
- Load one of Tray 1, Tray 2, Tray 3, and Tray4 with A4 paper. (Load one of them with Letter only if [Marketing Area] is [US].)
- Press the Start key to let the machine produce a test pattern.
- Place the test pattern produced on the original glass.
- Press the Start key and scan the test pattern.
- If the scanning finishes successfully, start the 2nd scanning following the instruction on the control panel.
- Set the test pattern rotated by 180 degrees on the original glass.
- Press the Start key and scan the test pattern.
- If the scanning finishes successfully, press [Print Test Pattern] to output the adjusted test pattern.
- Check the adjusted test pattern.
- To apply the adjusted correction value, press [Reflect Adj Values], then [Reflect] and [OK].
- NOTE
- Select [Do Not Reflect] and press [OK] not to apply the adjusted correct value. In this case, the corrected value is not applied but stored.
- Touching [Initialization] clears a stored correction value.