Konica Software Switch Settings (8 series)
01
02
03
04
05
06
07
08
09
10
11
12 Addition of Authentication Device
13
14
15
16
17
18
19
20
21
22
23
24
25 FW Version Function Setting
26
27
28
29
30
31
32
33 Renders some functions which were available when both administrator authentication and key counter were provided with when using the vendor , available only with admin authentication
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49 Upper limit of copies that can be input through the control panel setting
50
51 Settings for Life warning/replace display of units
69 When printing using manual bypass in custom size allows for printing only with a print driver ------- settings
70 Alarm sound and screen display for communication errors due to CSRC causes
72 Import/Export function of the address book through usb memory
121 Operation when a double feed is detected when adf is used
124 Function to restrict the file type of TX fax
135 Setting for the ID length of the HID Prox card
143 Expansion setting of the touch panel sensitive area when web browser function is used
145 Switching to auto detection for paper size in manual bypass tray
146 Setting for enabling use of non image area erase ,centering, and original size when book original is used in fax/scan mode
151 Setting for displaying or hiding the near empty display time
152 The email body print settings of the email RX print
155 Validation/invalidation of the debug setting of the log
157 Low Power Mode Settings
163 Setting for the auto execution of self diagnosis (full)
192 Sets whether to enable Android or iOS function
203 Setting to automatically change login authorization to a second user when the second user
attempts card authentication after a first user has been authenticated through card authentication
206 Setting whether to enable coverage counter
227 Setting for the display of consumable level and warning (Operatino panel,PSWC,Fiery)
230 Setting for the display of consumable level and warning (PSES,MIB,PrintFleet,SiteAudit)
71 Hide the colour copy option
159 HEX 08 Keeps SSD from going to sleep causing freezing issues.
172 HEX 05 Hide Marketplace app
SW 172 HEX 05 is the default HEX 01 hides the Marketplace app.
Konica Software Switch Settings :
10 Hex 02 makes a generic (Muratec) a Konica important so drivers can pick up all device options If you want to turn any Develop model into a Konica, you should put switch 10 into 02, not into 00.
12 Addition of Authentication Device
25 FW Version Function Setting
33 Renders some functions which were available when both administrator authentication and key counter were provided with when using the vendor , available only with admin authentication
49 Upper limit of copies that can be input through the control panel setting
50 ACS mode can be changed to limit the amount of time that the color IUs run. When the new mode is selected, the printer works as though doing monochrome printing without driving the color IUs.
51 Settings for Life warning/replace display of units
69 When printing using manual bypass in custom size allows for printing only with a print driver ------- settings
70 Alarm sound and screen display for communication errors due to CSRC causes
71 Hide color copy option
72 Import/Export function of the address book through usb memory
73 Hex 01 - This setting should allow you to hold scan settings and to be able to use the same address without touching the OK button after every job
121 Operation when a double feed is detected when adf is used
124 Function to restrict the file type of TX fax
135 Setting for the ID length of the HID Prox card
143 Expansion setting of the touch panel sensitive area when web browser function is used
145 Switching to auto detection for paper size in manual bypass tray
146 Setting for enabling use of non image area erase ,centering, and original size when book original is used in fax/scan mode
151 Setting for displaying or hiding the near empty display time
152 The email body print settings of the email RX print
155 Validation/invalidation of the debug setting of the log
157 Low Power Mode Settings
159 Hex 08 keeps SSD from going to sleep causing freezing issues
163 Setting for the auto execution of self diagnosis (full)
172 Hex 01 marketplace App is hidden ------Hex 05 is the default / marketplace App installed
192 Sets whether to enable Android or iOS function
203 Setting to automatically change login authorization to a second user when the second user
attempts card authentication after a first user has been authenticated through card authentication
206 Setting whether to enable coverage counter
227 Setting for the display of consumable level and warning (Operatino panel,PSWC,Fiery)
230 Setting for the display of consumable level and warning (PSES,MIB,PrintFleet,SiteAudit)
Password Protect The Utility Button
It is now possible to password protect the Utility Button on the Main Screen of the MFP.
This is useful in Multi User Environments to prevent unauthorised access to Utility, User Settings, Device Information, One Touch/ User Box Registration, Consumable Life, Banner Printing, Remote Panel Operation and so on.
With this set, the User will be prompted for a password when pressing the Utility Button - (The Password is the same as the Password used to access the Admin Mode).
Setting Procedure:
Access Tech Rep / System 2 / Software SW Setting:
Password protect access to Utility mode.
Software SW No.200 Hex 00 : Disabled (default)
Software SW No.200 Hex 20 : Enabled
This SW is available for the following models:
- All A3 "E series" devices (Must be on latest Firmware and Function Version)
- All A3 7 and 8 Series Devices
Note - None e series devices are NOT supported
Disable users from changing trays paper type
software switch 245 to 02
On color DinA4 machines, old bizhub C3350 (not "i" suffix), changing between "KM" or "Generic":
Software Swith Setting No. 13
hex 08 Generic.
hex 04 Konica Minolta.
33 | 00000000 | 00 | ||
33 | 00000001 | 01 | Renders some functions, whichwere available when both administrator authentication and key counter were provided with when using the vendor, available only with administer authentication. | Available only with administrator authentication |
33 | 00000010 | 02 | To use DipSW of " When the vendor device is off, job cancel timing is selectable with "immediately" or "after job completion". " in Vendor2 mode. | after job completion |
33 | 00000100 | 04 | When setting to vendor 2, make transfer fax function available. | Enabled |
33 | 00001000 | 08 | Allow/ Prohibit Web print when using Vender2. | Prohibit |
33 | 00010000 | 10 | Enables or disables the automatic tray switching function when the vendor is installed. | Enabled |
33 | 00100000 | 20 | Enables or disables the function that enables the box function when setting the key counter I/F vendor. | Enabled |
33 | 01000000 | 40 | Enables or disables the Real Mode Twain function when setting the vendor or management device. | Enabled |
33 | 10000000 | 80 |
71 | 00000000 | 00 | ||
71 | 00000001 | 01 | In the "Counter" screen, a total counter can be added at the top of the screen besides the left four counters. | Enabled |
71 | 00000010 | 02 | Enable/Disable the ability to hide color-related keys. | |
71 | 00000100 | 04 | Function that hard copies can not be seen by others after a print error | Enabled (To make hard copies unavailable to others: Disabled browsing) |
71 | 00001000 | 08 | To display the screen that asks a password, when logging to the user settings | Enabled |
71 | 00010000 | 10 | In the utility menu, after meter count is pressed , then check details is pressed, the print list in the serial number screen is pressed, the administrator password screen is displayed. |
Enabled |
71 | 00100000 | 20 | Hide Destination Type strings (eg. E-mail, SMB, FTP) on destination buttons in Scan/Fax Address Book. | Enable |
71 | 01000000 | 40 | Enable/Disable the function that allows setting only files that can be encrypted during Scan. | |
71 | 10000000 | 80 | Disable Public User deleting a job on the operation panel. |
Enabled (Public User cannot delete the job) |
217 00000000 hex 00
217 00000001 hex 01 MFP displayed toner empty message on the panel when Toner level at 20%.
217 00000010 hex 02 Reset the value of Toner level to 100% when replacement of new toner Enable cartridge.
217 00000100 hex 04 Fusing unit settings for the life warning/replace display of the units. Does not stop the life of the fixing unit.
217 00001 000 hex 08 Do not show the life warning/replace display of fusing unit. It does not stop life.